View and Download Calrec Artemis installation and technical manual online. Digital Broadcast Production Console. Artemis Music Mixer pdf manual download . Calrec Audio manufacture high quality production and live to air audio mixing consoles exclusively for broadcasters. Calrec offer the most comprehensive range. Run Waves plugins on your Calrec mixing consoles and enhance your live sound with Waves’ award-winning compressors, EQs, limiters, delays, and much .

Author: Tygolrajas Tygorg
Country: Albania
Language: English (Spanish)
Genre: Business
Published (Last): 18 June 2005
Pages: 64
PDF File Size: 17.84 Mb
ePub File Size: 20.35 Mb
ISBN: 694-7-68328-163-7
Downloads: 78151
Price: Free* [*Free Regsitration Required]
Uploader: Yotilar

Page Dynamic Range of the input, as the analogue input noise will be attenuated by the same amount as the signal, and the analogue input noise will still be dominant above the noise floor of the digital system. In the following pop-up, click Yes again to keep the format and xalrec incompatible features. It is also important to the ensure IP address compatibility of the systems being connected together. For more information on technician mode, and by SW-P and will work if patched e.

Distances are only limited by the SFP type.

Comments to this Manuals Your Name. Downmixes As well automatically. Please refer to the Hydra2 installation manual for more detail on the SW-P protocol and connection.

Calrec Artemis Installation And Technical Manual

Hydra2 Patchbays Hydra2 patchbays are created from the Required List for use in port patching. Surface Indication System Status screen now displays these as new messages and when the user clicks on the message, a 30 second timer starts which automatically clears the intermittent error from the message list. Please see the IP Address management section of this document for more details. To print the manual completely, please, download it. Dynamic Range of the input, as the analogue input noise will be attenuated by the same amount as the signal, and the analogue input noise will still be dominant above the noise floor of the digital system.

The and always open in their last used state. Lithium Battery Replacement Caution: Note, up to 20 characters can be entered as port labels. Bolt-down ‘ob’ Stands Figure 4. Page of Go.

  FEMTOCELL ALCATEL PDF

By pressing ‘print’ button you will print only current page. So huge, in fact, All modules and cards should be returned to Calrec Audio Limited in anti-static wrapping. All other routers on the same network need to be configured as Slaves. Once complete, change the panel mode to refresh the display. A blue background to a checkbox indicates that the whole folder is accessible, whilst a grey background indicates the whole folder is restricted. Some systems cakrec the count from 0, and therefore an offset of 1 would be required between the two sets of mapping data.

Page The following summarises key new features by the software version in which they were introduced. The Hydra2 Mabual, H2O, is an administrator-level user interface designed to provide control over the network without the use of an audio console.

Page 22 Changing fader Layers affects all the faders in the control surface calec layer or user splits have been put in place, or the fader has been locked to the surface. They can be used in multiple places on a console, on multiple consoles, as well as being sent directly to multiple outputs by cross-point routing, all simultaneously.

Fig 1 illustrates the hierarchy. For port patching purposes, Hydra Patchbay inputs are destinations and Hydra Patchbay outputs are sources. Meters can also be configured to display external inputs directly rather than via a meter selector. Confirming IPs To confirm the IP addresses associated with a processing rack, log in with administrator privileges to the PC associated with that rack and launch the Calrec Program Updater application.

Default Send Positions See Fig 11 below right. The 4U Artemis Light core is fitted with 9 x 40mm low power, low speed and low noise fans, mounted at the top of the rear of the core outputting air.

Artemis operator manual download ยป Calrec

Assist apps run on iPad devices which connect to the Calrec system through a wireless router, through which console functions can be controlled using CSCP. Ports that require the same label to be visible from each console should be edited using H2O to avoid having to name them on each console. It is important however in multi-rack systems to understand the network topology; a single connection between two routers is also limited to channels in each direction.

  ALELUIA J.CHEPPONIS PDF

Using spreadsheet software to view the file makes the data easier to read than using a text editor. These records are updated whenever a piece of hardware is dispatched to or received from a customer. In such cases the table will have several rows.

Once all columns are set to text, click Next. Page It may help to calrrec a show show file, the settings are restored as they later recall. Any DIP switches labelled Address 2 should all be set to the off position. The lower section of the panel works in conjunction Page 2 England UK equipment without notice. Sfp Slot Covers SFPs should always have a mxnual cover fitted into their optical transceiver end when no fibre is connected to them.

Full – sends the full surround signal out to containing APFL controls is explained the speakers.

Calrec ARTEMIS Operator’s Manual

The Manage metadata page in H2O displays a list of the metadata sets available for selection. This creates a star formation, in that all elements connect to a central point; the router card.

AES ports are numbered in stereo pairs and as such have a L or R suffix to denote the left and right legs manua, each pair. Serial Numbers All units produced by Calrec are given a serial number and are booked into a central record system at the time of manufacture. A master can have slaves but can also be made a slave of another master. SFP sockets to be customised to meet a range of requirements. Post delivery, the Calrec Customer Support team will take care of your technical enquiries.

MIX – button to route the mix minus signal to the selected direct output.